Bitmain Antminer DCRACK 36KW Asic Miners Air Cooling Cabinet
Description
Overview
The Antminer DCRACK is infrastructure rather than a miner. It stacks air-cooled ASICs in one cabinet and moves their heat out through a dedicated external cooler, so the machines sit in a controlled space instead of spreading across open shelving.
It is aimed at operators who already run, or plan to run, a sizeable fleet of air-cooled machines and want tidy cabling and a single point of power and cooling. A home setup will not have the supply or floor space it expects.
Specifications
| Manufacturer | Bitmain |
|---|---|
| Model | DCRACK |
| Version | V1 |
| Rack capacity | 47U |
| Maximum load, kW | 36kW |
| PUE at 25℃ ambient, 25℃ air supply (1-1) | 1.17 |
| Supply air temperature for classic server, ℃ | 18~27℃ |
| Server cabinet size (unpackaged) | 1600 x 1200 x 2350 mm |
| Server cabinet size (packaged) | 1720 x 1300 x 2400 mm |
| Server cabinet net weight | 668kg |
| Network connection mode | RJ45 Ethernet 10/100M |
| Server cabinet input voltage | 380-415v |
| Server cabinet input current, Amp (2-2) | 63 |
| Server cabinet fan rated power, W | 2500 |
| Server cabinet noise | 85db |
| Server cabinet fan size | 378 x 378 x 375mm |
| Server cabinet number of fans | 3 |
| External cooler size (unpackaged) | 1896 x 1026 x 2180 mm |
| External cooler size (packaged) | 2000 x 1130 x 2360 mm |
| External cooler net weight | 396Kg |
| External cooler input voltage | 380~415v |
| External cooler input current, Amp (2-2) | 63 |
| Heat pump rated power, kW | 8.5 |
| Heat pump COP (typical) | 4.75 |
| Heat pump refrigerant | R410A |
| Heat pump fan rated power, kW | 1.85 |
| Heat pump fan noise | 82db |
| Heat pump fan size | 805 x 805 x 21 mm |
| Heat pump number of fans | 2 |
| Refrigerant pump rated power, W | 550 |
| Refrigerant pump flow rate, m3/h | 1 |
| Refrigerant pump head, m | 48 |
| Refrigerant pump size | 420 x 152 x 202mm |
| Operating temperature | -20~45℃ |
| Installation distance (max), m (2-3) | 50 |
| Storage temperature | -20~70 |
| Humidity | 10~90% |
| Rack space | 47U for air-cooling servers |
| Sold as | 1Set |
Good to know
- Needs a 380-415v three-phase style supply, typical of industrial sites rather than homes.
- Air-cooled machines only; hydro-cooled miners do not belong in this cabinet.
- The cabinet and external cooler are separate units with their own dimensions, so plan floor space for both.
Additional information
| Delivery Batch | 36KW – 10th to 15th Days Delivery |
|---|
There are no question found.



Rating & Review